Comparison

Single pump or tandem pump: which one does the machine need?

Both appear in the same catalogue family and share most internal parts. The difference is how many circuits the pump serves and how it is driven - and the order code tells you which one you are looking at.

PropertyK3V112S (single)K3V112DTP (tandem)
Displacement112 mL/r112 mL/r (per pump)
Rated pressure34.3 MPa34.3 MPa
Max. speed2,700 min⁻¹2,700 min⁻¹
Max. input torque588 N·m588 N·m
CircuitOne pump feeding the main circuit; an auxiliary pump can be mounted behind itTwo pumps on one drive shaft feeding two circuits
Order codeS = single (centrifugal pump option)DT = tandem, DTP = tandem with PTO, DTH = control variant
Typical useSmaller machines, industrial open circuits, drilling rigs20-50 t excavators with two independently controlled circuits

How to tell them apart on the machine

Count the outlet ports

A tandem pump has two main outlets and two regulators; a single pump has one, with an optional auxiliary pump at the rear.

Read the order code

S means single, DT means tandem, and DTP adds a PTO. The suffix after the displacement code is what decides the regulator.

Check what the machine controls

Two independently controlled circuits need a tandem pump. Single-circuit machines and industrial open circuits usually do not.

Figures above come from the FLUTEK English catalogue dated 2024-11-25. Confirm shaft, flange and regulator variant on the unit nameplate before ordering.